Test
Report
No.
DJ20161017
Date:
OCT. 17, 2016 Page
ZHEJIANG DEJIA NEW MATERIAL CO., Ltd.
Tell: +86-573-87799855 87799051 Fax:+ 86-573-87799811
E-mail: [email protected]
#1, Luhong Road, Qianjiang Industrial Zone, Dingqiao Town, Haining City,314413, Zhejiang province, China
The following samples were submitted and identified on behalf of the client as:
Sample Description: White PVC Coated Fabric
Dejia Technology Center Ref No.: 20161017
Test Requested:
To determine the flammability (building materials class B2) in accordance with DIN 4102-1 (May 1998) Fire behaviour of building materials and elements Part 1: Classification of building materials, Requirements and testing
Test Results: --See attached sheet—
Conclusion:
The tested sample MEETS the flammability requirements of Class B2 of building materials under DIN 4102-1 (May 1998).
Test Period:
Sample Receiving Date : SEP. 25, 2016
Test Performing Date : SEP. 25, 2016 to OCT. 17, 2016
Signed for and on behalf of
Dejia-Technology Center:
Matt Meng
Engineer
I. Test conducted
This test was conducted as DIN 4102-1: 1998 Clause 6.2-Class B2 materials.
II. Sample details
General description |
White PVC Coated Fabric |
Color |
White |
Size of sample |
1000 mm X 190 mm & 190 mm X 90 mm |
Mass per unit area |
About 900g/m2 |
Conditioning
Prior to testing , the sample was conditioned at least 14 days to constant mass at a temperature of 23 ± 2oC
III. Test results
Normal Flammability Test according to DIN 4102-1 Clause 6.2
Flame application: bottom edge ignition & surface ignition
Normal Flammability Test according to DIN 4102-1 Clause 6.2
Flame application: [ √ ] bottom edge ignition, [ √ ] surface ignition
Bottom edge ignition |
|||||
Specimen No. |
1 |
2 |
3 |
4 |
5 |
Reaching the measuring mark within 20 seconds |
No |
No |
No |
No |
No |
Self extinguishing of the flame (s) |
0.97 |
1.02 |
0.85 |
0 |
0.34 |
End of afterflaming (s) |
0.97 |
1.02 |
0.85 |
0 |
0.34 |
End of afterglowing (s) |
0.97 |
1.02 |
0.85 |
0 |
0.34 |
Molten dripping |
No |
No |
No |
No |
No |
Smoke developments (visual impression) |
Slight |
||||
Surface ignition |
|||||
Reaching the measuring mark within 20 seconds |
No |
No |
No |
No |
No |
Self extinguishing of the flame (s) |
1.09 |
0.94 |
0 |
0.49 |
0.87 |
End of afterflaming (s) |
1.09 |
0.94 |
0 |
0.49 |
0.87 |
End of afterglowing (s) |
1.09 |
0.94 |
0 |
0.49 |
0.87 |
Molten dripping |
No |
No |
No |
No |
No |
Smoke developments (visual impression) |
Slight |
All timings are from the removing of ignition flame.
V. Criteria for classification for Class B2 (DIN 4102-1 Clause 6.2.2)
All materials expect flooring materials may be classed as B2 materials if they pass the ignitibility test, which shall be deemed passed if, for any of the five specimens tested, flaming does not reach the gauge mark within 20 seconds after flame application, either with bottom edge ignition or surface ignition.
***The end of this report***