Test Report No. DJ20161017 Date: OCT. 17, 2016 Page 4 of 4


ZHEJIANG DEJIA NEW MATERIAL CO., Ltd.

Tell: +86-573-87799855 87799051 Fax:+ 86-573-87799811

E-mail: [email protected]

#1, Luhong Road, Qianjiang Industrial Zone, Dingqiao Town, Haining City,314413, Zhejiang province, China

The following samples were submitted and identified on behalf of the client as:

Sample Description: White PVC Coated Fabric

Dejia Technology Center Ref No.: 20161017

Test Requested:

To determine the flammability (building materials class B2) in accordance with DIN 4102-1 (May 1998) Fire behaviour of building materials and elements Part 1: Classification of building materials, Requirements and testing


Test Results: --See attached sheet—

Conclusion:

The tested sample MEETS the flammability requirements of Class B2 of building materials under DIN 4102-1 (May 1998).


Test Period:

Sample Receiving Date : SEP. 25, 2016

Test Performing Date : SEP. 25, 2016 to OCT. 17, 2016


Signed for and on behalf of

Dejia-Technology Center:

TEST REPORT NO DJ20161017 DATE OCT 17 2016 PAGE

Matt Meng

Engineer


I. Test conducted

This test was conducted as DIN 4102-1: 1998 Clause 6.2-Class B2 materials.

II. Sample details

General description

White PVC Coated Fabric

Color

White

Size of sample

1000 mm X 190 mm & 190 mm X 90 mm

Mass per unit area

About 900g/m2

Conditioning

Prior to testing , the sample was conditioned at least 14 days to constant mass at a temperature of 23 ± 2oC

III. Test results

Normal Flammability Test according to DIN 4102-1 Clause 6.2

Flame application: bottom edge ignition & surface ignition










Normal Flammability Test according to DIN 4102-1 Clause 6.2

Flame application: [ √ ] bottom edge ignition, [ √ ] surface ignition

Bottom edge ignition

Specimen No.

1

2

3

4

5

Reaching the measuring mark within 20 seconds

No

No

No

No

No

Self extinguishing of the flame (s)

0.97

1.02

0.85

0

0.34

End of afterflaming (s)

0.97

1.02

0.85

0

0.34

End of afterglowing (s)

0.97

1.02

0.85

0

0.34

Molten dripping

No

No

No

No

No

Smoke developments (visual impression)

Slight

Surface ignition

Reaching the measuring mark within 20 seconds

No

No

No

No

No

Self extinguishing of the flame (s)

1.09

0.94

0

0.49

0.87

End of afterflaming (s)

1.09

0.94

0

0.49

0.87

End of afterglowing (s)

1.09

0.94

0

0.49

0.87

Molten dripping

No

No

No

No

No

Smoke developments (visual impression)

Slight

All timings are from the removing of ignition flame.





V. Criteria for classification for Class B2 (DIN 4102-1 Clause 6.2.2)

All materials expect flooring materials may be classed as B2 materials if they pass the ignitibility test, which shall be deemed passed if, for any of the five specimens tested, flaming does not reach the gauge mark within 20 seconds after flame application, either with bottom edge ignition or surface ignition.


TEST REPORT NO DJ20161017 DATE OCT 17 2016 PAGE

***The end of this report***