Continuous Monitoring data Data management

Continuous Monitoring Data Management

12/27/2012


Data Download (Log onto Wet Lab Computer)

On the Wet Lab computer – Open Loggernet and click Connect. Click on the station you want to download the data from and then Connect. Once connected – click Collect Now.


Once the data has downloaded – Click OK, and then close Loggernet. A Dat. file should be created and a file should be sent by e-mail to your inbox. Do not view the file during the collection process or it will not flow through the Execute Program properly and the Dat. file will sit in the holding location until the next time data is downloaded.



Data Management


Open C:/ CampbellSci / Loggernet / CR800 / Imported Files and look for the file you have just downloaded by date. Open the Dat. file and check the battery voltage for the station, and make sure all of the hourly readings are there without any holes or “NAN” values. The top and bottom readings will be listed side-by-side for each hour.


Open the link in the email to the data that you received. Scroll through the data and check to make sure all the same readings are present that were in the Dat file on the Wet Lab computer. Also take note of the top data especially – the quanta has a tendency to get hung up with the retreating tides every once in a while. This will be seen, for example, if the temperature suddenly varies wildly from one hour to the next, and the conductivity suddenly drops to a reading of 1 or 0. Another thing to note is the top depth. When the sonde is out of the water the depth should reflect this. Select any flawed data by clicking on and checking the box at the far left side of each flawed row. Once all data has been checked, return to the top of the page and click on the blue “Delete Selected Records” tab on the left. This will remove bad data from the database. Then close the link.