O
OGSB
41, Portovaya street, Kaliningrad, Russia, 236039
tel. (4012) 63 12 47, fax: (4012) 64 27 56,
www.ogsb.ru e-mail: [email protected]
Request for quotation (RFQ)
Oil Quality Measuring unit(BIK)
Please complete the information below and send to OGSB:
Tel. (4012) 31-07-28, Fax (4012) 31-07-29 e-mail: [email protected]
Contact Details
Client: |
|
Complete postal address: |
|
Contact person: |
|
Contact phone number: |
|
Fax: |
|
E-mail: |
|
Site Information
Name : |
|
|
Purpose: |
delivery |
acceptance |
Location: |
|
|
Startup date: |
|
|
Additional information: |
|
Working and ambient medium characteristics
Working medium (please specify or provide reference document/specification)) |
|
||
Design Ambient temperature, 0С |
min. |
|
max. |
|
|
|
|
Working medium design pressure, MPa |
min. |
|
max. |
|
|
|
|
Working medium operating pressure, MPa
|
min. |
|
max. |
|
|
|
|
Density, kg/m3 |
min. temperature |
|
max. temperature |
|
|
|
|
Kinematic viscosity, cSt |
min. temperature |
|
max. temperature |
|
|
|
|
Water content, % volume.: |
|
||
Solids content, % mass.: |
|
||
Chlorides content, mg/l |
|
||
Paraffin content, % mass. |
|
||
Nonassociated gas content, % volume. |
|
||
Hydrogen sulfide content, % mass. |
|
||
Saturated vapor pressure, kPa |
|
||
Operating temperature, 0С |
minimum |
|
maximum |
|
|
|
|
Operating relative Humidity % |
minimum |
|
maximum |
|
|
|
|
Storage and transportation temperature, 0С |
minimum |
|
maximum |
|
|
|
Process Data
Flowrate(in piping), t/hr (m3/hr) |
minimum |
|
maximum |
|
|
|
|
||
Measuring unit operation mode |
continuous |
periodic |
||
Valves control mode |
automatic |
manual |
||
Piping diameter (place of sampling device installation ), Dn, mm |
|
Equipment
Flowrate process scheme |
pump |
no pump |
||
Flushing system necessity(pump, vessel and etc.) |
yes |
no |
||
Fire alarm system |
yes |
no |
||
Flowrate regulation scheme |
frequency control |
automatic flow control |
manual flow control |
|
Specify the type of sampling device |
slot-type with lubrication |
slot-type without lubrication |
tube-type |
Instruments
densitometer |
backup densitometer
|
pressure transmitter
|
||
watercut meter |
backup watercut meter
|
temperature transmitter
|
||
viscometer |
backup viscometer |
nonassociated gas detection device
|
||
sulfur analyzer |
phase condition indicator |
manual sampler |
||
automatic sampler |
backup sampler |
Pycnometer ?? what is this
|
||
thermostat ?? temperature shown above |
||||
automatic online chromatograph (for gas condensate metering) |
Flow composition |
|||
Component |
Units |
Minimum |
maximum |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Oil Quality Measuring unit(BIK) placement
modular building |
modular building of technological unit |
indoors |
cabinet |
Data Processing System(SOI)
Operator control station |
main |
back up
|
|
panel mounted touchscreen |
|
flowmeter back up |
master controller backup |
Data processing system integration into the upper system |
data transfer interface |
data transfer protocol |
|
Preferred controller type |
|
Additional Information
Date of filling out the RFQ:
Страница
(6030154) 5 N240(E)(M31)H NATIONAL CERTIFICATE COMPUTERISED FINANCIAL SYSTEMS N4
0 HELSINKI UNIVERSITY OF TECHNOLOGY SYSTEMS ANALYSIS LABORATORY RESEARCH
017 SOUTHWEST ALUMINUM SYSTEMS CHANDLER ARIZONA PHONE 8005444044 SPECIFICATIONS